| TERMINAL TYPE AND QUANTITY | 17 TAB, SOLDER LUG |
| WINDING OPERATING VOLTAGE | 21.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 4.40 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING POWER RATING | 445.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 2 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 5.620 INCHES NOMINAL |
| BODY HEIGHT | 2.250 INCHES MAXIMUM |
| BODY WIDTH | 4.880 INCHES MAXIMUM |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
| MAXIMUM OPERATING TEMP | 70.0 DEG CELSIUS |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 10001 |
| DESIGN CONTROL REFERENCE | 2864399 |