5950-00-402-9184 TRANSFORMER,CURRENT Index 5950-00-402-9186 TRANSFORMER,ELECTRICAL

National Stock Number:
5950-00-402-9185

Federal Supply Class:
5950

National Item Identification Number:
004029185

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
25420172149ELECTRONIC TRANSFORMER CORP
65238328528ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST
SMC65238305853PTC TRANSFORMERS
PEI 746813483PRECISION ELECTRONICS, INC
SMC65238315634MAGNETIKA INC
65238331550L3HARRIS TECHNOLOGIES, INC.
SMC65238380063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
SMC65238380223UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC


Techincal Specification:
BODY HEIGHT3.750 INCHES NOMINAL
BODY LENGTH4.250 INCHES NOMINAL
BODY WIDTH3.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT4.380 INCHES MAXIMUM
MAXIMUM OPERATING TEMP144.0 FAHRENHEIT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.237 INCHES MINIMUM AND 0.247 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE(S) SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT4.0 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE28.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE28.50 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY7 TAB, SOLDER LUG