5950-00-394-0288 REACTOR Index 5950-00-394-0294 TRANSFORMER,POWER

National Stock Number:
5950-00-394-0289

Federal Supply Class:
5950

National Item Identification Number:
003940289

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
00510804386MAGNETEK INC HUNTINGTON DIV
00510805216PHOENIX TRANSFORMER CO
0051080LG51MAGNETEK INC LIGHTING PRODUCTS GROUP
00510819156MOOG INC
0051081L8V1MAGNETIKA INC
00510853342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
00510889870BERKSHIRE TRANSFORMER
BTC-1442489870BERKSHIRE TRANSFORMER


Techincal Specification:
TERMINAL TYPE AND QUANTITY10 TURRET
WINDING OPERATING VOLTAGE33.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
13.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT2.8 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
320.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
320.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING50.0 HERTZ MINIMUM AND
400.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH3.562 INCHES MAXIMUM
BODY HEIGHT4.875 INCHES MAXIMUM
BODY WIDTH3.062 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
MAXIMUM OPERATING TEMP80.0 DEG CELSIUS


Click here to Register for Free 30-day Trial