5950-00-326-1810 TRANSFORMER,POWER Index 5935-00-326-1826 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5950-00-326-1814

Federal Supply Class:
5950

National Item Identification Number:
003261814

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
2928145-110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
86311BX22EXXELIA USA, INC.
W863108715CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC


Techincal Specification:
TERMINAL TYPE AND QUANTITY16 WIRE HOOK
WINDING OPERATING VOLTAGE25.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
125.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
30.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT800.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED HOLE ALL GROUPINGS
MOUNTING FACILITY QUANTITY4 ALL GROUPINGS
THREAD SERIES DESIGNATORUNC ALL GROUPINGS
NOMINAL THREAD SIZE0.138 INCHES ALL GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.109 INCHES MINIMUM AND
2.141 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.734 INCHES MINIMUM AND
1.766 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH2.750 INCHES NOMINAL
BODY HEIGHT3.812 INCHES NOMINAL
BODY WIDTH2.375 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
TEST DATA DOCUMENT10001-2928145 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
MAXIMUM OPERATING TEMP155.0 DEG CELSIUS


Click here to Register for Free 30-day Trial