5340-00-287-8840 STRAP,RETAINING Index 9510-00-287-8851 BAR,METAL

National Stock Number:
5950-00-287-8845

Federal Supply Class:
5950

National Item Identification Number:
002878845

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1028114618876U S ARMY AVIATION AND MISSILE COMMAND
M2G3-3410-513013850TECHNIPOWER LLC
M2G3-3410-513024655GENRAD INC


Techincal Specification:
ADJUSTMENT DEVICE DRIVE TYPESHAFT SINGLE COMPONENT
ADJUSTMENT METHOD AND QUANTITY1 ADJUSTABLE CONTROL SINGLE COMPONENT
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.735 INCHES MINIMUM AND 2.765 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.735 INCHES MINIMUM AND 2.765 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING350.0 HERTZ MINIMUM AND 1.2 KILOHERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT9.594 INCHES NOMINAL
OVERALL LENGTH3.250 INCHES NOMINAL
OVERALL WIDTH3.250 INCHES NOMINAL
MAXIMUM OPERATING TEMP50.0 CELSIUS
MAXIMUM TRANSFORMER POWER RATING1.3 KILOVOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED HOLE(S) SINGLE GROUP
NOMINAL THREAD SIZE0.190 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT3.1 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE0.00 AC VOLTS MINIMUM AND 240.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE240.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
TERMINAL TYPE AND QUANTITY15 SCREW
THREAD SERIES DESIGNATORUNF SINGLE GROUP
TRANSFORMER WINDING CONNECTION TYPEWYE-WYE