5950-00-273-3959 REACTOR Index 6625-00-273-3961 PLATE,MOUNTING,FUSE

National Stock Number:
5950-00-273-3960

Federal Supply Class:
5950

National Item Identification Number:
002733960

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
00541902640MAGNETIKA
005419058R3GE AVIATION SYSTEMS LLC
00541915634MAGNETIKA INC
00541919623GE AVIATION SYSTEMS LLC
70191572149ELECTRONIC TRANSFORMER CORP
00541980223UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO SIX PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT6.500 INCHES MAXIMUM
OVERALL LENGTH4.875 INCHES MAXIMUM
OVERALL WIDTH3.125 INCHES MAXIMUM
MAXIMUM OPERATING TEMP155.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE(S) SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY AND ELEVEN SECONDARIES
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 11 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.0 AMPERES DC NOMINAL SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT7.0 AMPERES DC NOMINAL SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT5.0 AMPERES DC NOMINAL SINGLE COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE21.20 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE21.20 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE142.00 AC VOLTS MINIMUM AND 149.00 AC VOLTS MAXIMUM SINGLE COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE176.00 AC VOLTS NOMINAL AND 192.00 AC VOLTS NOMINAL AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE31.20 AC VOLTS MINIMUM AND 32.80 AC VOLTS MAXIMUM SINGLE COMPONENT FIRST SECONDARY
WINDING POWER RATING76.8 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING POWER RATING12.9 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
WINDING POWER RATING268.8 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY
WINDING POWER RATING283.7 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
TERMINAL TYPE AND QUANTITY16 TAB, SOLDER LUG AND 49 TURRET
TRANSFORMER WINDING CONNECTION TYPEWYE-DELTA-WYE


Click here to Register for Free 30-day Trial