| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 6.500 INCHES MAXIMUM |
| OVERALL LENGTH | 4.875 INCHES MAXIMUM |
| OVERALL WIDTH | 3.125 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 155.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
| MOUNTING METHOD | UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | ONE PRIMARY AND ELEVEN SECONDARIES |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 11 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 2.0 AMPERES DC NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| WINDING OPERATING CURRENT | 7.0 AMPERES DC NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| WINDING OPERATING CURRENT | 5.0 AMPERES DC NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| WINDING OPERATING CURRENT | 50.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 21.20 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| WINDING OPERATING VOLTAGE | 21.20 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| WINDING OPERATING VOLTAGE | 142.00 AC VOLTS MINIMUM AND 149.00 AC VOLTS MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| WINDING OPERATING VOLTAGE | 176.00 AC VOLTS NOMINAL AND 192.00 AC VOLTS NOMINAL AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 31.20 AC VOLTS MINIMUM AND 32.80 AC VOLTS MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| WINDING POWER RATING | 76.8 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING POWER RATING | 12.9 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| WINDING POWER RATING | 268.8 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY |
| WINDING POWER RATING | 283.7 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| TERMINAL TYPE AND QUANTITY | 16 TAB, SOLDER LUG AND 49 TURRET |
| TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA-WYE |