1660-00-199-1726 DUCT ASSEMBLY,AIR CONDITIONING-H Index 5950-00-199-1733 TRANSFORMER,POWER

National Stock Number:
5950-00-199-1729

Federal Supply Class:
5950

National Item Identification Number:
001991729

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
459385PC110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
C7475366PC124446GENERAL ELECTRIC COMPANY


Techincal Specification:
TERMINAL TYPE AND QUANTITY14 STANDOFF INSULATOR
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
5.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
780.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
1.14 AC KILOVOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT3.3 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
6.6 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
400.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH5.500 INCHES NOMINAL
BODY HEIGHT7.250 INCHES NOMINAL
BODY WIDTH4.500 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED