5910-00-175-4244 CAPACITOR,FIXED,GLASS DIELECTRIC Index 5905-00-175-4246 RESISTOR,FIXED,FILM

National Stock Number:
5950-00-175-4245

Federal Supply Class:
5950

National Item Identification Number:
001754245

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
208259-105614ALTEC LANSING CORP SOUND PRODUCTS DIV
208259-108742ASTEC AMERICA INC.
208259-119790DATA PRODUCTS CORP
208259-158634SAGA ENGINEERING CORP


Techincal Specification:
TERMINAL TYPE AND QUANTITY16 THREADED STUD
WINDING OPERATING VOLTAGE13.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
18.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
21.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
89.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
103.00 AC VOLTS NOMINAL AND
115.00 AC VOLTS NOMINAL AND
126.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT12.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
12.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
3.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY
200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING162.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
222.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
64.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
17.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING50.0 HERTZ NOMINAL OR
60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
5 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTHREADED HOLE ALL GROUPINGS
MOUNTING FACILITY QUANTITY4 ALL GROUPINGS
THREAD SERIES DESIGNATORUNF ALL GROUPINGS
NOMINAL THREAD SIZE0.190 INCHES ALL GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.437 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
INCLOSURE TYPEHERMETICALLY SEALED
BODY LENGTH5.820 INCHES MINIMUM AND
5.860 INCHES MAXIMUM
BODY HEIGHT5.340 INCHES MINIMUM AND
5.360 INCHES MAXIMUM
BODY WIDTH5.400 INCHES MINIMUM AND
5.440 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING; FIVE SECONDARY WINDINGS
MAXIMUM OPERATING TEMP105.0 DEG CELSIUS