5999-00-165-3691 CONTACT,ELECTRICAL Index 5999-00-165-3698 CONTACT,ELECTRICAL

National Stock Number:
5950-00-165-3694

Federal Supply Class:
5950

National Item Identification Number:
001653694

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
243157P294117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
921694315NEW ENGLAND TRANSFORMER CO INC


Techincal Specification:
TERMINAL TYPE AND QUANTITY22 WIRE LEAD
WINDING OPERATING VOLTAGE23.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
10.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
15.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
15.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
113.00 AC VOLTS MINIMUM AND
195.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT6.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
2.5 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
1.8 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
900.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING238.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
45.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
48.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
24.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING446.5 VOLT-AMPERE SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
6 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHODBRACKET AND
SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING SLOT WIDTH0.100 INCHES MINIMUM AND
0.160 INCHES MAXIMUM SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.740 INCHES MINIMUM AND
2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.927 INCHES MINIMUM AND
1.947 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEOPEN
BODY LENGTH2.970 INCHES MINIMUM AND
3.030 INCHES MAXIMUM
BODY HEIGHT1.280 INCHES MINIMUM AND
1.340 INCHES MAXIMUM
OVERALL WIDTH2.220 INCHES MINIMUM AND
2.280 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING; SIX SECONDARY WINDINGS
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA
MAXIMUM OPERATING TEMP155.0 DEG CELSIUS


Click here to Register for Free 30-day Trial