TERMINAL TYPE AND QUANTITY | 38 TURRET |
WINDING OPERATING VOLTAGE | 43.75 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 43.75 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 22.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 2.5 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 2.5 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 12.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 5.0 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 12 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE AND |
| THREE PHASE TO THREE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED STUD SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.609 INCHES MINIMUM AND |
| 2.641 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.109 INCHES MINIMUM AND |
| 2.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 3.875 INCHES MAXIMUM |
BODY HEIGHT | 3.062 INCHES MAXIMUM |
BODY WIDTH | 3.562 INCHES MAXIMUM |
OVERALL LENGTH | 4.255 INCHES NOMINAL |
OVERALL HEIGHT | 3.062 INCHES MAXIMUM |
OVERALL WIDTH | 3.562 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIFICATION/STANDARD DATA | 30003-247ASC1286-001FEATGONE PRIMARY AND FOURTEEN SECONDARY; SECONDARIES HAVE FULL WAVE RECTIFIED GOVERNMENT SPECIFICATION |
TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA AND |
| TAYLOR |