| TERMINAL TYPE AND QUANTITY | 15 STANDOFF, SOLDER LUG |
| WINDING OPERATING VOLTAGE | 1.0185 AC KILOVOLTS NOMINAL AND |
| 1.166 AC KILOVOLTS NOMINAL AND |
| 1.318 AC KILOVOLTS NOMINAL AND |
| 1.4655 AC KILOVOLTS NOMINAL AND |
| 2.484 AC KILOVOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 2.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 6.70 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 78.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| 6.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| 12.0 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| FREQUENCY RATING | 320.0 HERTZ MINIMUM AND |
| 1.76 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 4 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED STUD SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY LENGTH | 3.812 INCHES NOMINAL |
| BODY HEIGHT | 3.938 INCHES NOMINAL |
| BODY WIDTH | 3.188 INCHES NOMINAL |
| OVERALL LENGTH | 3.812 INCHES NOMINAL |
| OVERALL HEIGHT | 5.438 INCHES NOMINAL |
| OVERALL WIDTH | 3.188 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 80249 |
| DESIGN CONTROL REFERENCE | TR1180 |