5950-00-146-8184 COIL,RADIO FREQUENCY Index 5950-00-146-8187 TRANSFORMER,POWER

National Stock Number:
5950-00-146-8186

Federal Supply Class:
5950

National Item Identification Number:
001468186

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
T050-035-000107421L3HARRIS INTERSTATE ELECTRONICS CORPORATION


Techincal Specification:
TERMINAL TYPE AND QUANTITY32 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE23.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
23.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
41.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
41.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
3.8 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING380.0 HERTZ MINIMUM AND
420.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
11 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODFLANGE AND
UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.219 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH5.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
BODY LENGTH6.250 INCHES NOMINAL
BODY HEIGHT4.750 INCHES NOMINAL
BODY WIDTH5.000 INCHES NOMINAL
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURES1 PRIMARY WINDING; 11 SECONDARY WINDINGS;SECONDARY VOLTAGE AND CURRENT RATED AS DC
MAXIMUM OPERATING TEMP85.0 DEG CELSIUS