| BODY LENGTH | 16.000 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 14.950 INCHES MINIMUM AND 15.050 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 8.950 INCHES MINIMUM AND 9.050 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 10.690 INCHES NOMINAL |
| OVERALL WIDTH | 10.380 INCHES MINIMUM AND 10.500 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.450 INCHES MINIMUM AND 0.480 INCHES MAXIMUM SINGLE GROUP |
| MOUNTING METHOD | UNTHREADED HOLE(S) SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | COOLANT SYSTEM; CARRYING HANDLES 2 |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 2.1 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
| WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 5.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING POWER RATING | 10.5 KILOVOLT-AMPERES SINGLE COMPONENT ALL SECONDARY |
| TERMINAL TYPE AND QUANTITY | 24 THREADED STUD |
| TEST DATA DOCUMENT | 24930-160106 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |