| TERMINAL TYPE AND QUANTITY | 3 THREADED STUD |
| WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
| 0.00 AC VOLTS MINIMUM AND |
| 140.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| WINDING OPERATING CURRENT | 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT |
| WINDING POWER RATING | 940.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT |
| FREQUENCY RATING | 300.0 HERTZ MINIMUM AND |
| 1.2 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | FLANGE AND |
| UNTHREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING HOLE DIAMETER | 0.265 INCHES NOMINAL SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | OPEN |
| BODY LENGTH | 4.938 INCHES NOMINAL |
| BODY HEIGHT | 4.249 INCHES NOMINAL |
| BODY WIDTH | 4.500 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 80249 |
| DESIGN CONTROL REFERENCE | 890358-1 |