| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 30.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC INDUCTIVE LOAD |
| MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 21.0 VOLTS DC 125 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 52.0 MILLIMETERS NOMINAL |
| OVERALL LENGTH | 53.0 MILLIMETERS NOMINAL |
| OVERALL WIDTH | 32.0 MILLIMETERS NOMINAL |
| WINDING DC RESISTANCE RATING | 122.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 11 PIN ALL FUNCTIONS |
| TIME DELAY | 0.020 SECONDS NOMINAL FIXED OPERATE TIME |
| UNTHREADED MOUNTING HOLE DIAMETER | 3.2 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY |
| DUTY TYPE | CONTINUOUS |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC INDUCTIVE LOAD |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 30.0 DC |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 45.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 20.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND HERMETIC |