| DUTY TYPE | CONTINUOUS |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC INDUCTIVE LOAD |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FAILURE RATE SUFFIX LETTER | L |
| FREQUENCY IN HERTZ | 400.0 NOMINAL |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 122.0 AC |
| OVERALL LENGTH | 1.718 INCHES MAXIMUM |
| OVERALL WIDTH | 1.125 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 BRACKET(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |