NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC AND |
| 300.0 MILLIAMPERES AC RESISTIVE LOAD |
| 750.0 MILLIAMPERES DC AND |
| 200.0 MILLIAMPERES AC INDUCTIVE LOAD |
| 100.0 MILLIAMPERES DC LAMP LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
NOMINAL OPERATING CURRENT RATING AND TYPE | 18.0 MILLIAMPERES DC SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ENERGIZING ELEMENT |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.271 INCHES NOMINAL |
OVERALL WIDTH | 0.815 INCHES MAXIMUM |
OVERALL HEIGHT | 0.717 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
TEST DATA DOCUMENT | 81349-M5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL-R5757/13-126 GOVERNMENT SPECIFICATION |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-5757/13 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M5757/13-126 |