| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC AND 12.0 AMPERES AC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES DC AND 15.0 AMPERES AC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES DC AND 25.0 AMPERES AC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC AND 5.0 AMPERES AC LAMP LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 1.010 INCHES MAXIMUM |
| OVERALL LENGTH | 1.718 INCHES MAXIMUM |
| OVERALL WIDTH | 1.025 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 BRACKET(S) SINGLE MOUNTING FACILITY |
| SPECIAL FEATURES | 3PDT, 25 AMP (RESISTIVE), HERMETICALLY SEALED, 28 VDC COIL, 3% PER 10,000 FAILURE RATE, RAISED VERTICAL FLANGE MOUNT, RELAY |
| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 3C |
| SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-83536/32-003L GOVERNMENT SPECIFICATION |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 9 PIN CONTACTS |
| TERMINAL TYPE AND QUANTITY | 2 PIN ENERGIZING ELEMENT |
| TEST DATA DOCUMENT | 81349--83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |