| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 10.0 DC |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 1.406 INCHES MAXIMUM |
| OVERALL LENGTH | 1.906 INCHES MAXIMUM |
| OVERALL WIDTH | 1.531 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 11 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 17.5 MILLIAMPERES AC SINGLE WINDING |
| PRECIOUS MATERIAL AND LOCATION | CONTACT TERMINALS SILVER |
| PRECIOUS MATERIAL | SILVER |
| SPECIAL FEATURES | PINS 2, 5 AND 8 ARE NOT CONNECTED. |
| SPECIFICATION/STANDARD DATA | 18876-40163-91250 GOVERNMENT SPECIFICATION |
| WINDING DC RESISTANCE RATING | 2.25 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 11 QUICK DISCONNECT, MALE ALL FUNCTIONS |