| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.1 MILLIAMPERES DC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.2 MILLIAMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC AND 1.0 AMPERES AC RESISTIVE LOAD |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 125 DEG CELSIUS AND 28.0 VOLTS DC 125 DEG CELSIUS SINGLE WINDING |
| OVERALL LENGTH | 0.370 INCHES MAXIMUM |
| OVERALL WIDTH | 0.335 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | CIRUCLAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 8 TERMINAL SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER WITH NO EXTERNAL TERMINAL, ONE POSITION MOMENTARY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| SPECIAL FEATURES | FAILURE RATE LEVEL OF 1.000 PERCENT PER TEN THOUSAND CYCLES. |
| WINDING DC RESISTANCE RATING | 880.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| SPECIFICATION/STANDARD DATA | 81349--39016/15-080 GOVERNMENT SPECIFICATION |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-MIL-R-39016/15 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |