| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 0.300 INCHES MAXIMUM |
| OVERALL LENGTH | 0.375 INCHES NOMINAL |
| OVERALL WIDTH | 0.375 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 8 TERMINAL SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| SPECIAL FEATURES | FAILURE RATE: 0.1 PERCENT PER 10,000 CYCLES |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/17 GOVERNMENT SPECIFICATION |
| WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TIME DELAY | 0.0015 SECONDS MAXIMUM FIXED RELEASE TIME |
| TIME DELAY | 0.002 SECONDS MAXIMUM FIXED OPERATE TIME |