| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND |
| 1.0 AMPERES DC RESISTIVE LOAD |
| 28.0 MILLIAMPERES DC INDUCTIVE LOAD |
| 10.0 MILLIAMPERES DC LAMP LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 3.2 KILOHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 9 PIN ALL FUNCTIONS |
| TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.0075 SECONDS MAXIMUM FIXED RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT AND |
| VIBRATION PROOF AND |
| SHOCK PROOF |
| OVERALL LENGTH | 0.370 INCHES MAXIMUM |
| OVERALL WIDTH | 0.335 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.375 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| SPECIAL FEATURES | FAILURE RATE LEVEL OF 0.100 PERCENT PER 10,000 CYCLES |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 0.046 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |