| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.850 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 0.320 INCHES MAXIMUM |
| OVERALL LENGTH | 1.062 INCHES MAXIMUM |
| OVERALL WIDTH | 0.310 INCHES MAXIMUM |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.100 AMPERES DC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.125 AMPERES AC RESISTIVE LOAD AND 2.000 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.300 AMPERES DC INDUCTIVE LOAD |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING QUANTITY | 1 |
| SPECIFICATION/STANDARD DATA | 96906-MIL-R-39016/13M GOVERNMENT SPECIFICATION |
| TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD ALL FUNCTIONS |