| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.745 INCHES MINIMUM AND 2.755 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.870 INCHES MINIMUM AND 1.880 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 2.675 INCHES MAXIMUM |
| OVERALL LENGTH | 3.625 INCHES MAXIMUM |
| OVERALL WIDTH | 3.500 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.215 INCHES MINIMUM AND 0.218 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 THREADED STUD CONTACTS |
| TERMINAL TYPE AND QUANTITY | 2 SCREW ENERGIZING ELEMENT |
| TIME DELAY | 0.02 SECONDS MAXIMUM FIXED RELEASE TIME |
| TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |