| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC AND |
| 110.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 600.0 MILLIAMPERES AC AND |
| 600.0 MILLIAMPERES DC RESISTIVE LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 62.5 OHMS NOMINAL ALL WINDINGS |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 5.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| TIME DELAY | 0.003 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.002 SECONDS MAXIMUM FIXED RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 0.787 INCHES NOMINAL |
| OVERALL WIDTH | 0.390 INCHES NOMINAL |
| OVERALL HEIGHT | 0.366 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | METAL |