5945-01-317-0506 RELAY,ELECTROMAGNETIC Index 5945-01-317-0508 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-01-317-0507

Federal Supply Class:
5945

National Item Identification Number:
013170507

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS27418-1D96906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE3.937 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 10.0 AMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE20.0 AMPERES AC AND 10.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC AND 15.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS200.0 AC AND 28.0 DC
OVERALL HEIGHT1.680 INCHES MAXIMUM
OVERALL LENGTH1.531 INCHES MAXIMUM
OVERALL WIDTH1.531 INCHES MAXIMUM
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE0.138 INCHES SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIFICATION/STANDARD DATA96906-MS27418 GOVERNMENT STANDARD
WINDING DC RESISTANCE RATING160.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY8 WIRE HOOK ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THREAD CLASS2A SINGLE MOUNTING FACILITY
THREAD DIRECTIONRIGHT-HAND SINGLE MOUNTING FACILITY
THREAD QUANTITY PER INCH32 SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY
TIME DELAY0.01 SECONDS MAXIMUM FIXED RELEASE TIME
TIME DELAY0.02 SECONDS MAXIMUM FIXED OPERATE TIME


Click here to Register for Free 30-day Trial