| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| CUBIC MEASURE | 0.605 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | SHOCK PROOF AND VIBRATION RESISTANT AND HERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| FREQUENCY IN HERTZ | 60.0 NOMINAL OR 400.0 NOMINAL |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC INDUCTIVE LOAD |
| OVERALL HEIGHT | 1.125 INCHES MAXIMUM |
| OVERALL LENGTH | 1.025 INCHES MAXIMUM |
| OVERALL WIDTH | 0.525 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| SPECIAL FEATURES | FAILURE RATE 0.3 PERCENT PER 10,000 CYCLES; WEAPON SYSTEM ESSENTIAL |
| SPECIFICATION/STANDARD DATA | 96906-MS27401 GOVERNMENT STANDARD |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
| TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |