5945-01-313-7979 RELAY,ELECTROMAGNETIC Index 5945-01-313-7981 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-01-313-7980

Federal Supply Class:
5945

National Item Identification Number:
013137980

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
M83536/1081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M83536/10-022L81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M83536/10-022M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-83536/1081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-83536/1081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS27401-44X96906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.421 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CRITICALITY CODE JUSTIFICATIONFEAT
CUBIC MEASURE0.543 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS200.0 AC AND 28.0 DC
OVERALL HEIGHT1.010 INCHES MAXIMUM
OVERALL LENGTH1.025 INCHES MAXIMUM
OVERALL WIDTH0.525 INCHES MAXIMUM
MOUNTING FACILITY PATTERNIN-LINE SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY2 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE110.0 MILLIAMPERES DC SINGLE WINDING
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIAL FEATURESFAILURE RATE: 1.0 PERCENT PER 10,000 CYCLES
SPECIFICATION/STANDARD DATA81349--83536/10 GOVERNMENT SPECIFICATION
WINDING DC RESISTANCE RATING320.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY8 PIN ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.01 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME


Click here to Register for Free 30-day Trial