National Stock Number: 5945-01-300-7360
Federal Supply Class: 5945
National Item Identification Number: 013007360
Description: RELAY,ELECTROMAGNETIC
Detail: A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
|
Manufacturer Information:
| M39016/42-040L | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | | MIL-PRF-39016/42 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | | MIL-R-39016/42 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
|
Techincal Specification:
| DUTY TYPE | CONTINUOUS | | COIL QUANTITY | 1 | | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC | | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD | | OVERALL HEIGHT | 0.375 INCHES MAXIMUM | | OVERALL LENGTH | 0.370 INCHES MAXIMUM | | OVERALL WIDTH | 0.335 INCHES MAXIMUM | | MOUNTING FACILITY TYPE AND QUANTITY | 8 TERMINAL SINGLE MOUNTING FACILITY | | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY | | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING | | SPECIAL FEATURES | FAILURE RATE 3.0 PCT | | WINDING DC RESISTANCE RATING | 1600.0 OHMS NOMINAL SINGLE WINDING | | WINDING QUANTITY | 1 | | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS | | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
|
|