| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 600.0 MILLIAMPERES AC AND |
| 1.0 AMPERES DC RESISTIVE LOAD |
| 200.0 MILLIAMPERES DC INDUCTIVE LOAD |
| 100.0 MILLIAMPERES DC LAMP LOAD |
| TIME DELAY | 0.002 SECONDS NOMINAL FIXED OPERATE TIME |
| DUTY TYPE | CONTINUOUS |
| OVERALL LENGTH | 1.030 INCHES NOMINAL |
| OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 0.111 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 2 |
| WINDING QUANTITY | 2 |
| WINDING DC RESISTANCE RATING | 2.0 KILOHMS NOMINAL ALL WINDINGS |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE ALL FUNCTIONS |