| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| CRITICALITY CODE JUSTIFICATION | SPCL |
| ENVIRONMENTAL PROTECTION | HERMETIC AND VIBRATION PROOF AND SHOCK PROOF |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
| OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.280 INCHES MAXIMUM |
| OVERALL LENGTH | 0.780 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| SPECIAL FEATURES | LEAD LG 0.500 IN. MIN.,TEMP RANGE M 65 DEG C TO P 125 DEG C |
| SPECIAL TEST FEATURES | FAILURE RATE LEVEL /PERCENT PER 10000 CYCLES/ 0.1 PERCENT |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/9 GOVERNMENT SPECIFICATION |
| WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |