| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.436 INCHES MINIMUM AND 1.456 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 0.911 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | COLD RESISTANT AND HEAT RESISTANT AND SHOCK RESISTANT AND VIBRATION PROOF |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC AND 12.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND 5.0 AMPERES DC MOTOR LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 1.280 INCHES MAXIMUM |
| OVERALL LENGTH | 1.718 INCHES MAXIMUM |
| OVERALL WIDTH | 0.525 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING SLOT WIDTH | 0.140 INCHES MINIMUM AND 0.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 110.0 MILLIAMPERES AC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-6106/19 GOVERNMENT SPECIFICATION |
| WINDING QUANTITY | 1 |
| SURFACE TREATMENT | SOLDER CONTACT |
| TERMINAL TYPE AND QUANTITY | 5 PIN ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TIME DELAY | 0.01 SECONDS NOMINAL FIXED OPERATE AND RELEASE TIME |