| PILE-UP MAIN CONTACT FORM ARRANGEMENT | 24A |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 125.0 MILLIAMPERES AC AND |
| 1.0 AMPERES DC RESISTIVE LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 50 TAB, SOLDER LUG ALL FUNCTIONS |
| TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.004 SECONDS MAXIMUM FIXED RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 3.125 INCHES MAXIMUM |
| OVERALL WIDTH | 1.031 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.844 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.099 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 48 SINGLE MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 9.163 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | PLASTIC |