| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 18.254 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETICHERMETIC |
| FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 30.0 DC |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 18.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 3.250 INCHES MAXIMUM3.250 INCHES MAXIMUM |
| OVERALL LENGTH | 2.370 INCHES MAXIMUM2.370 INCHES MAXIMUM |
| OVERALL WIDTH | 2.370 INCHES MAXIMUM2.370 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 35.0 MILLIAMPERES DC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING DC RESISTANCE RATING | 840.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 11 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |