| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 80.976 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC AND 100.0 AMPERES DC MOTOR LOAD |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 4.531 INCHES MAXIMUM |
| OVERALL LENGTH | 4.235 INCHES MAXIMUM |
| OVERALL WIDTH | 4.220 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.233 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 1.23 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
| TIME DELAY | 0.015 SECONDS MAXIMUM FIXED RELEASE TIME |
| TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |