| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC AND |
| 2.0 AMPERES DC RESISTIVE LOAD |
| 750.0 MILLIAMPERES DC INDUCTIVE LOAD |
| 160.0 MILLIAMPERES DC LAMP LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
| TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.180 INCHES MAXIMUM |
| OVERALL WIDTH | 0.410 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.600 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
| FEATURES PROVIDED | POLARIZED |
| SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT |
| TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/6 GOVERNMENT SPECIFICATION |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 0.290 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | METAL |
| SPEC/STD CONTROLLING DATA | |
| MANUFACTURERS CODE | 81349 |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39016/6 |
| DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39016/6-129P |