| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.1 AMPERES DC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.2 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
| OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
| OVERALL LENGTH | 0.375 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| WINDING DC RESISTANCE RATING | 1.025 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |