| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 0.205 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| OVERALL HEIGHT | 2.100 INCHES MAXIMUM |
| OVERALL LENGTH | 1.040 INCHES MAXIMUM |
| OVERALL WIDTH | 0.084 INCHES MINIMUM AND 0.094 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 16 PIN ALL FUNCTIONS |
| TIME DELAY | 0.010 SECONDS MAXIMUM FIXED OPERATE TIME |
| TIME DELAY | 0.050 SECONDS MAXIMUM FIXED RELEASE TIME |