| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 110.0 AC AND |
| 110.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND |
| 1.0 AMPERES DC RESISTIVE LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 110.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| FREQUENCY IN HERTZ | 400.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE ALL FUNCTIONS |
| TIME DELAY | 0.05 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 1.500 INCHES NOMINAL |
| OVERALL WIDTH | 1.500 INCHES NOMINAL |
| OVERALL HEIGHT | 2.500 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 5.625 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | METAL |