| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 2.0 KILOHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 8 TAB, SOLDER LUG ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| OVERALL LENGTH | 1.688 INCHES NOMINAL |
| OVERALL WIDTH | 0.906 INCHES NOMINAL |
| OVERALL HEIGHT | 1.188 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 1.817 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CONTACT SURFACE TREATMENT | GOLD FLASH |
| PRECIOUS MATERIAL | GOLD |
| PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |