| NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND |
| 10.0 AMPERES DC RESISTIVE LOAD |
| 8.0 AMPERES AC AND |
| 8.0 AMPERES DC INDUCTIVE LOAD |
| 2.0 AMPERES AC AND |
| 2.0 AMPERES DC LAMP LOAD |
| 4.0 AMPERES AC AND |
| 4.0 AMPERES DC MOTOR LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 20 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.708 INCHES MAXIMUM |
| OVERALL WIDTH | 1.410 INCHES NOMINAL |
| OVERALL HEIGHT | 1.010 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.462 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |