| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.580 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.600 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| PROPRIETARY CHARACTERISTICS | PACS |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING SLOT WIDTH | 0.180 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.190 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 375.0 VOLTS AC NONSTANDARD TEMP SINGLE WINDING |
| OVERALL HEIGHT | 1.955 INCHES NOMINAL |
| OVERALL LENGTH | 2.390 INCHES NOMINAL |
| OVERALL WIDTH | 2.000 INCHES NOMINAL |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 3 QUICK DISCONNECT, MALE ALL FUNCTIONS |