| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC AND |
| 2.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 100.0 OHMS NOMINAL SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 40.0 MILLIAMPERES DC SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.453 INCHES MAXIMUM |
| OVERALL WIDTH | 0.400 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.483 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| TEST DATA DOCUMENT | 81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-5757/13 GOVERNMENT SPECIFICATION |
| SPEC/STD CONTROLLING DATA | |
| MANUFACTURERS CODE | 81349 |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-5757/13 |
| DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M5757/13-052 |