| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND |
| 30.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND |
| 15.0 AMPERES DC RESISTIVE LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
| TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
| TIME DELAY | 1.50 SECONDS MINIMUM AND |
| 15.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 3.250 INCHES MAXIMUM |
| OVERALL WIDTH | 3.090 INCHES MAXIMUM |
| OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| 4 THREADED HOLE SECOND MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
| RECTANGULAR SECOND MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
| 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM AND |
| 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
| 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
| THREAD CLASS | 2B SECOND MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
| THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 45.392 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | PLASTIC |