| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.870 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.870 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 75.0 AMPERES AC AND 75.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 15000.0 AC AND 15000.0 DC |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 4.630 INCHES MAXIMUM |
| OVERALL LENGTH | 2.500 INCHES NOMINAL |
| OVERALL WIDTH | 2.500 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| WINDING DC RESISTANCE RATING | 225.0 OHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-83725/15 GOVERNMENT SPECIFICATION |
| TERMINAL TYPE AND QUANTITY | 2 TURRET ENERGIZING ELEMENT |
| TERMINAL TYPE AND QUANTITY | 3 SCREW CONTACTS |
| TEST DATA DOCUMENT | 81349-MIL-R-83725 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |