| DUTY TYPE | CONTINUOUS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.421 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FEATURES PROVIDED | POLARIZED |
| FREQUENCY IN HERTZ | 50.0 MINIMUM AND 400.0 MAXIMUM |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| OVERALL HEIGHT | 1.435 INCHES MAXIMUM |
| OVERALL LENGTH | 1.718 INCHES MAXIMUM |
| OVERALL WIDTH | 0.525 INCHES MAXIMUM |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| SPECIFICATION/STANDARD DATA | 96906-MS27401 GOVERNMENT STANDARD |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
| TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
| TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |