| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.365 INCHES MINIMUM AND 2.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| COIL QUANTITY | 1 |
| CUBIC MEASURE | 7.789 CUBIC INCHES |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES DC MOTOR LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES DC INDUCTIVE LOAD |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES DC RESISTIVE LOAD |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC LAMP LOAD |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| OVERALL HEIGHT | 2.365 INCHES MINIMUM AND 2.385 INCHES MAXIMUM |
| OVERALL LENGTH | 2.780 INCHES MINIMUM AND 2.840 INCHES MAXIMUM |
| OVERALL WIDTH | 1.090 INCHES MINIMUM AND 1.150 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 120.0 MILLIAMPERES DC SINGLE WINDING |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES MINIMUM AND 0.202 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| WINDING QUANTITY | 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| TERMINAL TYPE AND QUANTITY | 5 SCREW ALL FUNCTIONS |
| TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE TIME |
| TIME DELAY | 0.04 SECONDS MAXIMUM FIXED RELEASE TIME |