| DUTY TYPE | CONTINUOUS |
| COIL QUANTITY | 1 |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
| OVERALL HEIGHT | 0.275 INCHES MAXIMUM |
| OVERALL LENGTH | 0.370 INCHES MAXIMUM |
| OVERALL WIDTH | 0.370 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| WINDING DC RESISTANCE RATING | 1.56 KILOHMS NOMINAL SINGLE WINDING |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
| TIME DELAY | 0.003 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |