5330-01-100-8476 SEAL,PLAIN Index 5945-01-100-8479 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-01-100-8478

Federal Supply Class:
5945

National Item Identification Number:
011008478

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
5945PL09574929009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
5945PL20741739009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
AN3353-143999THE BOEING COMPANY
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24187-D196906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24187-D296906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24187-D2A9271GORIZIANE GROUP SPA
Z00.N7733060187TBMF0086SOCATA


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE16.849 CUBIC INCHES
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE50.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE50.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE50.0 AMPERES DC MOTOR LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT2.906 INCHES MAXIMUM
OVERALL LENGTH2.812 INCHES MAXIMUM
OVERALL WIDTH2.062 INCHES MAXIMUM
MOUNTING FACILITY PATTERNIN-LINE SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIFICATION/STANDARD DATA96906-MS24187 GOVERNMENT STANDARD
UNTHREADED MOUNTING HOLE DIAMETER0.214 INCHES NOMINAL SINGLE MOUNTING FACILITY
WINDING DC RESISTANCE RATING104.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY6 THREADED STUD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.02 SECONDS MAXIMUM FIXED OPERATE TIME
TIME DELAY0.018 SECONDS MAXIMUM FIXED RELEASE TIME


Click here to Register for Free 30-day Trial