| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
| 3.0 AMPERES AC INDUCTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| TIME DELAY | 5.00 SECONDS MINIMUM AND |
| 180.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 2.500 INCHES NOMINAL |
| OVERALL WIDTH | 1.520 INCHES MAXIMUM |
| OVERALL HEIGHT | 5.000 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.177 INCHES NOMINAL SINGLE MOUNTING FACILITY |